Northwestern University Ryan Center | Goettsch Partners

Northwestern University Ryan Center

The new music and communication building is located just south of Northwestern University’s Pick-Staiger Concert Hall and Regenstein Hall of Music, on the southeastern edge of the Evanston campus. Sited on a prime parcel fronting Lake Michigan and a new arts green, the building is envisioned as a signature facility. Designed to wrap and connect with Regenstein Hall, the building enables the School of Music to consolidate its programs for the first time ever.

photography by ©Tom Rossiter

The dynamic, Z-shaped plan of the building mass defines the eastern edge of the arts green then jogs to the western edge of the lake. A large atrium divides this form, providing the main entry and gathering space and offering clear views of the lake. Targeted for LEED Gold status, the building offers a variety of innovative features including a double-skin facade and grey water system. All spaces met enormous acoustical requirements, including the opera rehearsal room and choral recital.

photography by ©Tom Rossiter

The recital hall is the building’s crown jewel. Featuring a 40-foot-high glass wall, the space sets performers against a dramatic backdrop of Lake Michigan and the Chicago skyline.The detail needed to consider the overall acoustical challenges of a monumental 42’ x 40‘ glass wall and the resultant acoustical reflections within the recital hall. The vertical supports of the glass wall are hung from above and achieve their slenderness by using highly tensioned horizontal cables that are anchored to the recital hall’s massive concrete side walls.

photography by ©Tom Rossiter

Solar/blackout shades are hidden above the ceiling, contained within the accessible cavity so that they don’t interfere with the acoustics of the hall. The inner glass wall is tilted inward to prevent an echo from being heard by the audience. Acoustical banners can be employed inside the recital hall to fine tune the acoustics during a performance.

The horizontal weaving wood ribbon panels of the recital hall were designed to absorb the sound reflections from the glass wall so that the entire room could work in harmony to create a unique vision opportunity without sacrificing acoustical performance.

photography by ©Tom Rossiter

Project Info
Architects: Goettsch Partners
Location: Evanston, USA
Area: 14120.0 sqm
Year: 2015
Type: Cultural Center
Photographs: Tom Rossiter
Structural Engineering: Thornton Tomasetti
MEP/FP Engineering: Cosentini Associates
General Contractor: Power Construction Company
Landscape Consultant: Hoerr Schaudt Landscape Architects
Acoustics & Audio/Video Consultant: Kirkegaard Associates
Lighting Design & Theatre Planning: Schuler Shook
Elevator Consultant: Jenkins & Huntington
Civil Engineering: V3 Companies of Illinois
Sustainable Design Consultant: Atelier Ten
Owner Cost Consultant: Lend Lease
Design Cost Consultant: Construction Cost Systems
Leed Consultant: Epstein
Hardware Consultant: Opening Solutions
Energy-Environment Technical Consulting: E Cube
Soils Engineer: AECOM
Client: Northwestern University

Arch2O.com
Logo
Send this to a friend
01-Northwestern-University-Ryan-Center-Overall
01-Northwestern-University-Ryan-Center-Overall
03-Northwestern-University-Ryan-Center-Aerial
03-Northwestern-University-Ryan-Center-Aerial
04-Northwestern-University-Ryan-Center-South-Facade
04-Northwestern-University-Ryan-Center-South-Facade
05-Northwestern-University-Ryan-Center-East-Facade
05-Northwestern-University-Ryan-Center-East-Facade
06-Northwestern-University-Ryan-Center-West-Facade
06-Northwestern-University-Ryan-Center-West-Facade
07-Northwestern-University-Ryan-Center-Main-Entry
07-Northwestern-University-Ryan-Center-Main-Entry
08-Northwestern-University-Ryan-Center-Atrium
08-Northwestern-University-Ryan-Center-Atrium
09-Northwestern-University-Ryan-Center-Corridor
09-Northwestern-University-Ryan-Center-Corridor
10-Northwestern-University-Ryan-Center-Common-Area
10-Northwestern-University-Ryan-Center-Common-Area
11-Northwestern-University-Ryan-Center-Recital-Hall
11-Northwestern-University-Ryan-Center-Recital-Hall
12-Northwestern-University-Ryan-Center-Black-Box
12-Northwestern-University-Ryan-Center-Black-Box
13-Northwestern-University-Ryan-Center-Choral
13-Northwestern-University-Ryan-Center-Choral
14-Northwestern-University-Ryan-Center-South-Facade-Panorama
14-Northwestern-University-Ryan-Center-South-Facade-Panorama
J:CAD�8300PlansPresentationPRESENTATION_PFL_B1 Sheet (1)
J:CAD�8300PlansPresentationPRESENTATION_PFL_B1 Sheet (1)
J:CAD�8300PlansPresentationPRESENTATION_PFL_02 11x17 (1)
J:CAD�8300PlansPresentationPRESENTATION_PFL_02 11x17 (1)
J:CAD�8300PlansPresentationPRESENTATION_PFL_03 11x17 (1)
J:CAD�8300PlansPresentationPRESENTATION_PFL_03 11x17 (1)
J:CAD�8300PlansPresentationPRESENTATION_PFL_04 11x17 (1)
J:CAD�8300PlansPresentationPRESENTATION_PFL_04 11x17 (1)
J:CAD�8300PlansPresentationPRESENTATION_PFL_05 11x17 (1)
J:CAD�8300PlansPresentationPRESENTATION_PFL_05 11x17 (1)
Site---Ground-Floor-Plans-copy
Site---Ground-Floor-Plans-copy
J:CAD�8300PlansPresentationPRESENTATION_PFL_01 11x17 (1)
J:CAD�8300PlansPresentationPRESENTATION_PFL_01 11x17 (1)
West-Elevation
West-Elevation
East-Elevation
East-Elevation
Sec
Sec
Recital-Hall-Section
Recital-Hall-Section
Planning-Diagrams-copy
Planning-Diagrams-copy
Planning-Diagrams-copy1
Planning-Diagrams-copy1
Planning-Diagrams-copy2
Planning-Diagrams-copy2
Planning-Diagrams-copy3
Planning-Diagrams-copy3
Axonometric-Floor-Plans-copy2
Axonometric-Floor-Plans-copy2
Axonometric-Floor-Plans-copy1
Axonometric-Floor-Plans-copy1
Axonometric-Floor-Plans-copy3
Axonometric-Floor-Plans-copy3